Barrier and Measuring Tool (APP) A tool belonging to PT PLN (Persero) which functions to limit the electric power used and measure the use of electrical energy
Ampere (A) Unit of Electric Current
Electricity Supporting Business Entity (BUPTL): Installers engaged in the construction and installation of electricity equipment
Load Costs (BB) The cost component in the electricity bill, which is a fixed amount, is calculated based on the connected power
Late Fee (BK) Is a fee charged to customers for not meeting the obligation to pay PLN bills on time
Connection Fee (BP) The fee that must be paid to PLN by a potential customer or customer to obtain a new connection or add power
Bulk (C) Namely the tariff class for the purpose of selling in bulk (Bulk) to Business License Holders
Current Transformer or Current Transformer (CT) Tool to reduce electric current for energy measurement purposes
Connected Power The amount of power agreed by PLN and the customer in the Power Purchase Agreement which is the basis for calculating the cost of the load
Power factor or Cos. Comparison of power consumption in Watts with power consumption in Volt-Amperes
Voltage Unbalance Factor Comparison of negative sequence voltage components to positive sequence voltage components
Hertz (HZ) A unit of electrical frequency
Running time kWh consumption in one month divided by the connected kVA
The JTL Extra High Voltage Network (JTET) operated by the TET covering all parts of the network and its equipment
The JTL Medium Voltage Network (JTM) operated by TM which includes all parts of the network and its equipment
Low Voltage Network (JTR) JTL operated by TR which covers all parts of the network and its equipment
High Voltage Network (JTT) JTL operated with TT covering all parts of the network and its equipment
Electricity Network (JTL) PLN's electricity distribution / distribution system that is operated by TR, TM, TT or TET
JBST Limited Sale and Purchase of Electricity
Kilo Meter Circuit (kms) A unit of length for a three-phase electric power transmission or distribution network
Kilo Volt Ampere (kVA) One thousand Volt Ampere, is a unit of power
Kilo Volt (kV) One thousand volts, is a unit of electric voltage
Kilo Watt (kW) Unit of actual (active) electric power
Kilo Watt Hour (kWh) Unit of real (active) electrical energy
kVA max-Meter Tool to measure the highest power consumption in units of kVA for a month divided by the kVA connected during one month, especially for customers B3, I4 and I3 arc furnaces, T
KVARh Kilo Volt Ampere Reactive Hour, unit of pseudo (reactive) electrical energy
kVARh Meter Measuring tool for pseudo (reactive) electrical energy consumption
kWh Meter Measuring tool for electrical energy consumption
kWh Double Rate Meter kWh Meter which has two registers, one register to measure energy consumption in WBP and the other register to measure energy in LWBP
kWh Meter Single Rate kWh Meter which has one register to measure energy consumption
LWBP Outside Peak Load Time (22.00 - 18.00)
M / TR, TM, TT Multipurpose Tariff intended for electricity users who require special services, both in Low Voltage, Medium Voltage and High Voltage
MVA Mega Volt Ampere (Million Volt Ampere)
Public Street Lighting Tax (PPJU) A tax paid by all PLN customers, collected by PLN and subsequently deposited in the local government treasury
Contact Board (PHB) Part of the customer's electrical installation that is used to distribute electricity
PB New Linking
PD Add Power / Change Power
Complete Termination Termination for continual distribution of electricity to the customer's installation by taking part or all of the equipment for the distribution of electricity to the customer's installation
Temporary Termination. Temporary termination of electricity supply to the customer's installation
Public Street Lighting (PJU) Lighting for roads and public infrastructure that is legally installed by the regional government or other official bodies and is legally supplied with electricity from PLN
Control of Electricity Usage (P2TL) Examination by PLN of PLN installations and customer installations in order to control the use / utilization of electricity
Potential Transformer (Voltage Transformer) A device to reduce the voltage required specifically for measuring electrical energy or other electrical safety and lowering equipment
The service entry line (SMP) cable owned by PLN that connects the Low Voltage network with the APP installed at the customer's house
Direct Connection Is a JTL or SL connection including the equipment so that electricity is transmitted without going through APP
Electrical Power Connection (STL) Conductors below or above the ground including their equipment as part of the PLN installation which is a connection
bro between PLN's JTL and the customer's installation
Electricity Bill Calculation of costs for the consumption of power and electrical energy by customers every month
Subsequent Claims Receivables later as a result of an adjustment to the provisions or as a result of a violation
Basic Electricity Tariff (TDL) Applicable government regulations regarding tariff groups and the selling price of electricity provided by PLN
Extra High Voltage (TET) System voltage above 245,000 Volts
Medium Voltage (TM) System voltages above 1,000 volts to 35,000 volts
Low Voltage (TR) System voltages up to 1,000 volts
High Voltage (TT) System voltage above 35,000 Volts to 245,000 Volts
Joint Connection Point The closest point to a customer where other customers are connected to JTR or JTM or JTr or JTET
Customer Security Deposit (UJL) Money which is a guarantee for power consumption and electrical energy while being a customer
Advance Electricity Bill (UMTL) Receipt of payment for power consumption and electrical energy preceding the power and energy transfer transaction
Volt Ampere (VA) Unit of power (blind power)
Volt (V) Unit of Electric Voltage
Peak Load Time (WBP) Time from 18.00 to 22.00 local time
Watt Real power unit
Hopefully Helpful, ... ^ _ ^